La prótesis de cadera con recubrimiento de vidrio. Primeros resultados con 2 años de evolución
Total hip prosthesis with glass coating. First results after two years of follow-up
J. L. VILLAR GONZÁLEZ. M. FRAGA. R. LEÓN. H. R. FERNANDEZ,S. MOSQUERA. J. R. CAEIRO. C. PÉREZ y O. MONTERO Servicio de Cirugía Ortopédica y Traumatología.Complejo Hospitalario Santa María Madre y Cabaleiro Goas. Orense.
Recepción:
07/11/2008
Aceptación:
07/11/2008
Publicación:
07/11/2008
Métricas
83
Visualizaciones
Compartir
Compartir
Resumen (ES)
This work analizes the first clinical and radiological results of a cementless hip
prosthesis with glass coating at metaphyseal level (CRM prosthesis). A total of 80 arthroplasties implanted
since may 1991 to 1994 were studied with a two year follow-up. The clinical assesment was
done by the modified Harris score, being satisfactory in 90% of the patients. The radiological study
demonstrated good fixation and orientation of the prosthetic compounds in 72 cases. The prosthetic
model studied provides a security mechanism both for primary and secondary fixation of the
femoral stem and acetabular cup.
prosthesis with glass coating at metaphyseal level (CRM prosthesis). A total of 80 arthroplasties implanted
since may 1991 to 1994 were studied with a two year follow-up. The clinical assesment was
done by the modified Harris score, being satisfactory in 90% of the patients. The radiological study
demonstrated good fixation and orientation of the prosthetic compounds in 72 cases. The prosthetic
model studied provides a security mechanism both for primary and secondary fixation of the
femoral stem and acetabular cup.
Palabras clave (ES):
Artroplastia
Vidrio
Fijación
Biovidrio
Prótesis
Cadera
Recubrimiento
Resumen (EN)
This work analizes the first clinical and radiological results of a cementless hip
prosthesis with glass coating at metaphyseal level (CRM prosthesis). A total of 80 arthroplasties implanted
since may 1991 to 1994 were studied with a two year follow-up. The clinical assesment was
done by the modified Harris score, being satisfactory in 90% of the patients. The radiological study
demonstrated good fixation and orientation of the prosthetic compounds in 72 cases. The prosthetic
model studied provides a security mechanism both for primary and secondary fixation of the
femoral stem and acetabular cup.
prosthesis with glass coating at metaphyseal level (CRM prosthesis). A total of 80 arthroplasties implanted
since may 1991 to 1994 were studied with a two year follow-up. The clinical assesment was
done by the modified Harris score, being satisfactory in 90% of the patients. The radiological study
demonstrated good fixation and orientation of the prosthetic compounds in 72 cases. The prosthetic
model studied provides a security mechanism both for primary and secondary fixation of the
femoral stem and acetabular cup.
Explorar
Artículos
Volúmenes
Sobre la revista
Más leídos
Surgiceloma como complicación de tenodesis extraarticular de Lemaire modificada asociada a ligamentoplastia del cruzado anterior
Revista Española de Cirugía Osteoarticular
Solución límite para recambio de prótesis total de cadera con cotilo osteointegrado: presentación de casos
Revista Española de Cirugía Osteoarticular
Radioterapia a bajas dosis en artrosis: ¿una opción terapéutica real o un efecto placebo sofisticado?
Revista Española de Cirugía Osteoarticular
Osteomielitis esclerosante de Garré: reporte de dos casos de una enfermedad inusual
Revista Española de Cirugía Osteoarticular
Uso de placa puente dorsal: una alternativa en fracturas de muñeca catastróficas
Revista Española de Cirugía Osteoarticular