31-182

Valor de la resonancia magnética en el diagnóstico de las lesiones de rodilla

The value of the magnetic resonance imaging in the macnosis of knee lesions

E. VILLANUEVA GARCÍA*, V. BOSCH REIG** y C. LÓPEZ-CASQUERO** * Servicio de Traumatología y Ortopedia. Hospital Arnau de Villanova. Valencia.**Sección de Traumatología y Ortopedia. Hospital Universitario La Fe. Valencia.
Recepción:
06/11/2008
Aceptación:
06/11/2008
Publicación:
06/11/2008


Métricas


55

Visualizaciones


2

Descargas


Compartir

Compartir

Resumen (ES)

In order to evaluate the efficacy of magnetic resonance imaging (MRI) in the diagnosis
of knee patology, the MRI charts of 60 patients were reviewed, considering as a reference
the findings of the arthroscopy. Sensitivity, specificity, predictive positive value, predictive negative
value and predictive global value of the technique were determined. The results showed a sensitivity
of 95%, a specificity of 85% and a predictive global value of 89% for the meniscus. A sensitivity
of 75%, a specificity of 94% and a predictive global value of 90% for the anterior cruciate
ligament. The articular cartilage abnormalities had a sensitivity of 54% a specificity of 100% and
a predictive global value of 82%.

Palabras clave (ES):

Diagnóstico
LesiónRodilla
Resonancia
Rotura
Menisco
Ligamento
RM
Magnética

Resumen (EN)

In order to evaluate the efficacy of magnetic resonance imaging (MRI) in the diagnosis
of knee patology, the MRI charts of 60 patients were reviewed, considering as a reference
the findings of the arthroscopy. Sensitivity, specificity, predictive positive value, predictive negative
value and predictive global value of the technique were determined. The results showed a sensitivity
of 95%, a specificity of 85% and a predictive global value of 89% for the meniscus. A sensitivity
of 75%, a specificity of 94% and a predictive global value of 90% for the anterior cruciate
ligament. The articular cartilage abnormalities had a sensitivity of 54% a specificity of 100% and
a predictive global value of 82%.

Explorar

Artículos


Volúmenes


Sobre la revista


Más leídos

Surgiceloma como complicación de tenodesis extraarticular de Lemaire modificada asociada a ligamentoplastia del cruzado anterior

Revista Española de Cirugía Osteoarticular


Uso de placa puente dorsal: una alternativa en fracturas de muñeca catastróficas

Revista Española de Cirugía Osteoarticular


No todo es "cut-out": reclasificación de las complicaciones mecánicas del tornillo cefálico del clavo intramedular.

Revista Española de Cirugía Osteoarticular


Solución límite para recambio de prótesis total de cadera con cotilo osteointegrado: presentación de casos

Revista Española de Cirugía Osteoarticular


Radioterapia a bajas dosis en artrosis: ¿una opción terapéutica real o un efecto placebo sofisticado?

Revista Española de Cirugía Osteoarticular