38-215

Tratamiento de las fracturas y de sus secuelas con el fijador externo Hoffmann II

Treatment of fractures and its consequences with the Hoffman II external fixator

M. MALILLOS TORÁN, A. MARTINEZ MARTÍN, J. CUENCA ESPIERREZ, A. HERRERA RODRÍGUEZ SERVICIO DE CIRUGÍA ORTOPÉDICA Y TRAUMATOLOGÍA. HOSPITAL UNIVERSITARIO MIGUEL SERVET. ZARAGOZA.
Recepción:
15/09/2008
Aceptación:
15/09/2008
Publicación:
15/09/2008


Métricas


63

Visualizaciones


Compartir

Compartir

Resumen (ES)

We report our experience in the treatment of fractures
and its consequences with the Hoffmann II external
fixator. We have operated on 34 patients. In 44% of cases
there were open fractures, in 44% closed fractures, and the
remaining cases were non-unions. The average follow-up
was 14 months (range: 12-18). In 85% of cases, we used the
external fixator as a definitive treatment, and in the remaining
as a temporary treatment, until the patient or injury conditions
improved and it could be applied a definitive treatment. The
average union time was 21 weeks (range: 6-27) and there
were not cases of non-union or nerve or vessel injuries. The
obtained results with this external fixator are satisfactory,
being its application versatile and easy, therefore we recommend
its use in the treatment of fractures.

Palabras clave (ES):

Fijador
Tratamiento
externo
Fijación
externa
Hoffmann
Fractura
Secuela

Resumen (EN)

We report our experience in the treatment of fractures
and its consequences with the Hoffmann II external
fixator. We have operated on 34 patients. In 44% of cases
there were open fractures, in 44% closed fractures, and the
remaining cases were non-unions. The average follow-up
was 14 months (range: 12-18). In 85% of cases, we used the
external fixator as a definitive treatment, and in the remaining
as a temporary treatment, until the patient or injury conditions
improved and it could be applied a definitive treatment. The
average union time was 21 weeks (range: 6-27) and there
were not cases of non-union or nerve or vessel injuries. The
obtained results with this external fixator are satisfactory,
being its application versatile and easy, therefore we recommend
its use in the treatment of fractures.

Explorar

Artículos


Volúmenes


Sobre la revista


Más leídos

Surgiceloma como complicación de tenodesis extraarticular de Lemaire modificada asociada a ligamentoplastia del cruzado anterior

Revista Española de Cirugía Osteoarticular


Uso de placa puente dorsal: una alternativa en fracturas de muñeca catastróficas

Revista Española de Cirugía Osteoarticular


No todo es "cut-out": reclasificación de las complicaciones mecánicas del tornillo cefálico del clavo intramedular.

Revista Española de Cirugía Osteoarticular


Solución límite para recambio de prótesis total de cadera con cotilo osteointegrado: presentación de casos

Revista Española de Cirugía Osteoarticular


Radioterapia a bajas dosis en artrosis: ¿una opción terapéutica real o un efecto placebo sofisticado?

Revista Española de Cirugía Osteoarticular