54-280
Ángulo de pendiente tibial posterior Slope en prótesis total de rodilla. Diferencias entre alineación Intra o Extramedular y su repercusión sobre el rango de movilidad postoperatorio.
CRUZADO-NAVARRO B, MIFSUT-MIEDES D, SILVESTRE-MUÑOZ A.
Recepción:
14/03/2020
Aceptación:
14/03/2020
Publicación:
14/03/2020
Métricas
113
Visualizaciones
6
Descargas
Compartir
Compartir
Resumen (ES)
Introduction: The aim of this work was to compare the posterior tibial slope of the tibial component after performing a totalknee arthroplasty, as an intramedullary or extramedullary guide was used during the surgical technique, as well ascomparing the range of mobility obtained according to the Instrumentation used. Material and methods: We conducted adescriptive, retrospective, observational study of a series of 57 patients operated in our Center during 2012 and 2013, withthe same model of total knee arthroplasty (Sigma PS® DePuy), divided into two homogeneous groups in terms of age,sex, degree of osteoarthritis evolution, the first with patients operated by extramedullary guidance and the second byintramedullary guidance. A radiographic study was performed, measuring the posterior slope angle in the sagittal plane.The range of mobility achieved after arthroplasty and implant survival was studied. Results: Together, in both groups,measurements of the posterior slope angle were made, which was 4.35º preoperative average. In groups, the meanpostoperative posterior fall angle was 4.04 ° in the patients who underwent an EM guide, while those who underwent anIM guide the mean was 1.76 °; the differences being statistically significant. The range of mobility in the ATRs operated byintramedullary guidance was 102.7º on average (range 80-125º), while in the group where the extramedullary guide wasused, it was 104.3º (range 80-130º) no these differences being statistically significant. Regarding the survival of theimplant, during the study period two cases of patients undergoing surgery for the replacement of prostheses were found,both of which belonged to the Extramedullary guide group. Conclusion: The posterior drop angle, for the same PSprosthesis model, was statistically different according to the guide used, being within the 3-7º range in the group where theextramedullary guide was used; but despite these differences, no impact on the range of mobility was observed. Currently,it is recommended to restore the patient''''s posterior tibial slope, and in cases with a slope greater than 10º use a PS ATR.
Palabras clave (ES):
Total
knee
arthroplasty;
Knee
instability;
Knee
reconstruction;
Extramedullary;
Intramedullary;
MetaAnalysis
slope.
Resumen (EN)
Introduction: The aim of this work was to compare the posterior tibial slope of the tibial component after performing a totalknee arthroplasty, as an intramedullary or extramedullary guide was used during the surgical technique, as well ascomparing the range of mobility obtained according to the Instrumentation used. Material and methods: We conducted adescriptive, retrospective, observational study of a series of 57 patients operated in our Center during 2012 and 2013, withthe same model of total knee arthroplasty (Sigma PS® DePuy), divided into two homogeneous groups in terms of age,sex, degree of osteoarthritis evolution, the first with patients operated by extramedullary guidance and the second byintramedullary guidance. A radiographic study was performed, measuring the posterior slope angle in the sagittal plane.The range of mobility achieved after arthroplasty and implant survival was studied. Results: Together, in both groups,measurements of the posterior slope angle were made, which was 4.35º preoperative average. In groups, the meanpostoperative posterior fall angle was 4.04 ° in the patients who underwent an EM guide, while those who underwent anIM guide the mean was 1.76 °; the differences being statistically significant. The range of mobility in the ATRs operated byintramedullary guidance was 102.7º on average (range 80-125º), while in the group where the extramedullary guide wasused, it was 104.3º (range 80-130º) no these differences being statistically significant. Regarding the survival of theimplant, during the study period two cases of patients undergoing surgery for the replacement of prostheses were found,both of which belonged to the Extramedullary guide group. Conclusion: The posterior drop angle, for the same PSprosthesis model, was statistically different according to the guide used, being within the 3-7º range in the group where theextramedullary guide was used; but despite these differences, no impact on the range of mobility was observed. Currently,it is recommended to restore the patient''''s posterior tibial slope, and in cases with a slope greater than 10º use a PS ATR.
Explorar
Artículos
Volúmenes
Sobre la revista