Nuevas tecnologías en la corrección de las deformidades de la columna vertebral. Sistema TranspineNew technologies in correcting deformities of the spine. TRANSPINE®

New technologies in correcting deformities of the spine. TRANSPINE® System.

D. BONETE LLUCH, L. A. PÉREZ MILLÁN. SERVICIO DE TRAUMATOLOGÍA Y CIRUGÍA ORTOPÉDICA DEL HOSPITAL UNIVERSITARIO Y POLITÉCNICO LA FE. VALENCIA.
Recepción:
29/05/2014
Aceptación:
29/05/2014
Publicación:
29/05/2014


Métricas


54

Visualizaciones


2

Descargas


Compartir

Compartir

Resumen (ES)

Correction systems of the latest generation for the treatment of spinal deformities have aroused great controversy. We conducted a historical review of the surgical treatment and we describe a new system that allows the use of hybrid assemblies (claws, pedicle screws and pull cable wires). A total of 200 patients from 2004 to 2010 with idiopathic scoliosis, congenital neuropathic were operated with the Transpine® system using hybrid assembly. The correction percentage of postoperative obtained was analyzed. Change 70% and 30% respectively of the coronal and sagittal axis was observed (P <0.001). The angular losses were <10º. The Transpine® system let surgeons to perform uncomplicated hybrid safely assemblies for treatment of deformities. The results are comparable with those published in the literature.

Palabras clave (ES):

Transpine
Deformidad
Raquis
quirúrgico
Tratamiento
Corrección
Escoliosis
Instrumentación
Sistema

Resumen (EN)

Correction systems of the latest generation for the treatment of spinal deformities have aroused great controversy. We conducted a historical review of the surgical treatment and we describe a new system that allows the use of hybrid assemblies (claws, pedicle screws and pull cable wires). A total of 200 patients from 2004 to 2010 with idiopathic scoliosis, congenital neuropathic were operated with the Transpine® system using hybrid assembly. The correction percentage of postoperative obtained was analyzed. Change 70% and 30% respectively of the coronal and sagittal axis was observed (P <0.001). The angular losses were <10º. The Transpine® system let surgeons to perform uncomplicated hybrid safely assemblies for treatment of deformities. The results are comparable with those published in the literature.

Explorar

Artículos


Volúmenes


Sobre la revista


Más leídos

Surgiceloma como complicación de tenodesis extraarticular de Lemaire modificada asociada a ligamentoplastia del cruzado anterior

Revista Española de Cirugía Osteoarticular


Uso de placa puente dorsal: una alternativa en fracturas de muñeca catastróficas

Revista Española de Cirugía Osteoarticular


No todo es "cut-out": reclasificación de las complicaciones mecánicas del tornillo cefálico del clavo intramedular.

Revista Española de Cirugía Osteoarticular


Solución límite para recambio de prótesis total de cadera con cotilo osteointegrado: presentación de casos

Revista Española de Cirugía Osteoarticular


Radioterapia a bajas dosis en artrosis: ¿una opción terapéutica real o un efecto placebo sofisticado?

Revista Española de Cirugía Osteoarticular