48-255

Rotura no traumática de componente cerámica-cerámica en PTC. Presentación de un caso y revisión de la literatura.

Nontraumatic rupture of THR ceramic-ceramic component. Case report and literature review.

L. ARBELOA-GUTIÉRREZ, J. DUART-CLEMENTE, I. BERMEJO-ARANA, A. D’ARRIGO, A. ARENAS PLANELLES. DEPARTAMENTO DE CIRUGÍA ORTOPÉDICA Y TRAUMATOLOGÍA. COMPLEJO HOSPITALARIO DE NAVARRA. PAMPLONA.
Recepción:
18/02/2014
Aceptación:
18/02/2014
Publicación:
19/02/2014


Métricas


68

Visualizaciones


2

Descargas


Compartir

Compartir

Resumen (ES)

Fractures of ceramic components used in total hip replacement (THR) are uncommon. To report a case of early non-traumatic rupture ceramic-ceramic component in THR and review the literature regarding this complication. A 58 years diagnosed with avascular necrosis of the femoral head, was operated by THR, a ceramic-on -ceramic. At 4 months after surgery, without previous trauma, fracture was observed ceramic dome of the prosthesis. The patient required replacement, using the ceramic-on-polyethylene. The fracture of ceramic components is rare. The failure may be due to a manufacturing defect or implant placement. Patients should be informed about the possibility
of having this complication before implantation of a THR ceramic-on-ceramic.

Palabras clave (ES):

Cerámica
Rotura
Fractura
Cadera
Prótesis
Artroplastia

Resumen (EN)

Fractures of ceramic components used in total hip replacement (THR) are uncommon. To report a case of early non-traumatic rupture ceramic-ceramic component in THR and review the literature regarding this complication. A 58 years diagnosed with avascular necrosis of the femoral head, was operated by THR, a ceramic-on -ceramic. At 4 months after surgery, without previous trauma, fracture was observed ceramic dome of the prosthesis. The patient required replacement, using the ceramic-on-polyethylene. The fracture of ceramic components is rare. The failure may be due to a manufacturing defect or implant placement. Patients should be informed about the possibility
of having this complication before implantation of a THR ceramic-on-ceramic.

Explorar

Artículos


Volúmenes


Sobre la revista


Más leídos

Surgiceloma como complicación de tenodesis extraarticular de Lemaire modificada asociada a ligamentoplastia del cruzado anterior

Revista Española de Cirugía Osteoarticular


Uso de placa puente dorsal: una alternativa en fracturas de muñeca catastróficas

Revista Española de Cirugía Osteoarticular


No todo es "cut-out": reclasificación de las complicaciones mecánicas del tornillo cefálico del clavo intramedular.

Revista Española de Cirugía Osteoarticular


Solución límite para recambio de prótesis total de cadera con cotilo osteointegrado: presentación de casos

Revista Española de Cirugía Osteoarticular


Radioterapia a bajas dosis en artrosis: ¿una opción terapéutica real o un efecto placebo sofisticado?

Revista Española de Cirugía Osteoarticular