El cotilo de impactación en las artroplastias de cadera

Impacted acetabular component in total hip authroplasty

D.HERNANDEZ VAQUERO, M.J. OLAY GAYOSO Y J.L.BARRERA CADENAS SERVICIO DE TRAUMATOLOGÍA Y ORTOPEDIA. HOSPITAL SAN AGUSTÍN. AVILÉS. DEPARTAMENTO DE CIRUGÍA. FACULTAD DE MEDICINA. OVIEDO.
Recepción:
15/09/2008
Aceptación:
15/09/2008
Publicación:
15/09/2008


Métricas


51

Visualizaciones


Compartir

Compartir

Resumen (ES)

The acetabular fixation by impaction has advantages
on other systems of fixing in the cementless arthroplasties
of the hip. Permit a better contact between implant and
bone and it does not need destruction of the receiving bony
surface. The new designs for fixation by impaction are manufactured
in titanium alloys and possess a rugged surface
cover at the same time with hydroxiapatite-coated. Some
models as the arthroplasty Bihapro possess fins for primary
stability in your external curbing to avoid the initial rotary
mobilization. This system of fixation is showing good results in
the known experience and though the periods of follow-up
are yet short, the obtained bony integration is satisfactory.
We presented the results of 1107 Bihapro cups implanted with
a follow-up from one to seven years, that they have followed
a computed protocol. In only a case was presented lossening
of the component that specified review surgery.

Palabras clave (ES):

cementado
Impactación
Fijación
No
Impactado
Cadera
Prótesis
Artroplastia
total
Cotilo
Acetábulo

Resumen (EN)

The acetabular fixation by impaction has advantages
on other systems of fixing in the cementless arthroplasties
of the hip. Permit a better contact between implant and
bone and it does not need destruction of the receiving bony
surface. The new designs for fixation by impaction are manufactured
in titanium alloys and possess a rugged surface
cover at the same time with hydroxiapatite-coated. Some
models as the arthroplasty Bihapro possess fins for primary
stability in your external curbing to avoid the initial rotary
mobilization. This system of fixation is showing good results in
the known experience and though the periods of follow-up
are yet short, the obtained bony integration is satisfactory.
We presented the results of 1107 Bihapro cups implanted with
a follow-up from one to seven years, that they have followed
a computed protocol. In only a case was presented lossening
of the component that specified review surgery.

Explorar

Artículos


Volúmenes


Sobre la revista


Más leídos

Surgiceloma como complicación de tenodesis extraarticular de Lemaire modificada asociada a ligamentoplastia del cruzado anterior

Revista Española de Cirugía Osteoarticular


Uso de placa puente dorsal: una alternativa en fracturas de muñeca catastróficas

Revista Española de Cirugía Osteoarticular


No todo es "cut-out": reclasificación de las complicaciones mecánicas del tornillo cefálico del clavo intramedular.

Revista Española de Cirugía Osteoarticular


Solución límite para recambio de prótesis total de cadera con cotilo osteointegrado: presentación de casos

Revista Española de Cirugía Osteoarticular


Radioterapia a bajas dosis en artrosis: ¿una opción terapéutica real o un efecto placebo sofisticado?

Revista Española de Cirugía Osteoarticular