20-118
Injertos osteocondrales. Estudio experimental en el conejo
F. GOMAR-SANCHO, E. GASTALDI CLÍNICA QUIRÚRGICA UNIVERSITARIA. VALENCIA CATEDRA DE CIRUGÍA ORTOPÉDICA y TRAUMATOLOGÍA
Recepción:
31/03/2009
Aceptación:
31/03/2009
Publicación:
31/03/2009
Métricas
52
Visualizaciones
Compartir
Compartir
Resumen (ES)
An experimental study in 24 rabbits is reported; osteochondral defects in the weightbearingarea of the cartilage of the medial condile were made, being filled with an osteochondralgraft taken from the femoral articular surface of the femoral patella joint. Theanimals were sacrified after three days, in one, two, three, four, six, eight, ten, twelve,sixteen, eighteen and twenty weeks.The examination microscopy and triptium timidine uptake showed the cartilage toremain alive along the all experience, increasing its thickness until the surrounding cartilageleve), but without any real continuity. The bone part of the graft is rebuilt perfectlyby creeping substitution.
Palabras clave (ES):
Reparación
Rodilla
Experimental
Osteocondral
Articular
Injerto
Lesión
Cartílago
Defecto
Resumen (EN)
An experimental study in 24 rabbits is reported; osteochondral defects in the weightbearingarea of the cartilage of the medial condile were made, being filled with an osteochondralgraft taken from the femoral articular surface of the femoral patella joint. Theanimals were sacrified after three days, in one, two, three, four, six, eight, ten, twelve,sixteen, eighteen and twenty weeks.The examination microscopy and triptium timidine uptake showed the cartilage toremain alive along the all experience, increasing its thickness until the surrounding cartilageleve), but without any real continuity. The bone part of the graft is rebuilt perfectlyby creeping substitution.
Explorar
Artículos
Volúmenes
Sobre la revista
Más leídos
Surgiceloma como complicación de tenodesis extraarticular de Lemaire modificada asociada a ligamentoplastia del cruzado anterior
Revista Española de Cirugía Osteoarticular
Uso de placa puente dorsal: una alternativa en fracturas de muñeca catastróficas
Revista Española de Cirugía Osteoarticular
No todo es "cut-out": reclasificación de las complicaciones mecánicas del tornillo cefálico del clavo intramedular.
Revista Española de Cirugía Osteoarticular
Solución límite para recambio de prótesis total de cadera con cotilo osteointegrado: presentación de casos
Revista Española de Cirugía Osteoarticular
Radioterapia a bajas dosis en artrosis: ¿una opción terapéutica real o un efecto placebo sofisticado?
Revista Española de Cirugía Osteoarticular