22-130

Estudio histoquímico de la físis tibial de ratas diabéticas jóvenes

G. GARCES M A R T I N, J. A. MEDINA HENRIQUEZ, A. LÓPEZ ALONSO y J. A. RAMÍREZ GONZÁLEZ Unidad de Investigación en Patología del Aparato Locomotor. Departamento de Anotomía del Colegio Universitario de las Palmas.
Recepción:
16/01/2009
Aceptación:
16/01/2009
Publicación:
04/02/2009


Métricas


50

Visualizaciones


1

Descargas


Compartir

Compartir

Resumen (ES)

A histochemical study, Alcian Blue technique, was made on the growth plate of the tibia in streptozotocin induced diabetic male rats. Results were compared with a controlgroup. After the first week, although diabetic growth plates were thinner than controls, no differences in staining were found; from the second week diabetic epiphyseal plates progressively showed less avidity for Alcian Blue than control plates, mainly at the resting and proliferative zones. Because of the early changes in the growth plates of the rats, doser observation of diabetic children, specially those diagnosed with delay, is advised.

Palabras clave (ES):

Experimental
Físis
Tibial
Diabetes
Cartílago
Crecimiento
Histoquímica
Tibia

Resumen (EN)

A histochemical study, Alcian Blue technique, was made on the growth plate of the tibia in streptozotocin induced diabetic male rats. Results were compared with a controlgroup. After the first week, although diabetic growth plates were thinner than controls, no differences in staining were found; from the second week diabetic epiphyseal plates progressively showed less avidity for Alcian Blue than control plates, mainly at the resting and proliferative zones. Because of the early changes in the growth plates of the rats, doser observation of diabetic children, specially those diagnosed with delay, is advised.

Explorar

Artículos


Volúmenes


Sobre la revista


Más leídos

Surgiceloma como complicación de tenodesis extraarticular de Lemaire modificada asociada a ligamentoplastia del cruzado anterior

Revista Española de Cirugía Osteoarticular


Uso de placa puente dorsal: una alternativa en fracturas de muñeca catastróficas

Revista Española de Cirugía Osteoarticular


No todo es "cut-out": reclasificación de las complicaciones mecánicas del tornillo cefálico del clavo intramedular.

Revista Española de Cirugía Osteoarticular


Solución límite para recambio de prótesis total de cadera con cotilo osteointegrado: presentación de casos

Revista Española de Cirugía Osteoarticular


Radioterapia a bajas dosis en artrosis: ¿una opción terapéutica real o un efecto placebo sofisticado?

Revista Española de Cirugía Osteoarticular