Resumen (ES)

Between 2000 2002 we treated 18 patients with
symptomatic osteoarthritis or osteonechrosis of hip, with
uncemneted Thrust Plate Protesis (Sulzer) and tantalium acetabular
componente Hedrocel (Zimmer), with ceramic-polyethylene
pair. The average age of the patients was 46,7 years
(range:35-61), and the average follow-up of 42 months.
Clinical evaluation was done with Merle D'Augbigné Postel's
scale obtaining 38,8 % of excellent results, 22,2 % of good
results, 11,1 % fair and 27,4 % poor (5 cases). Four cases needed
re-operation for loosening of the femoral stem. There was
no failure of the acetabular component. The hip artrhroplasty
in the young patients need solutions with the minor resection
of bone, but this model of femoral stem does not give a satisfactory
result, therefore we have abandoned it.

Palabras clave (ES):

Minivástago
Prótesis
Cadera
Tantalio
Artroplastia
total
Vástago
Cotilo
Acetábulo
Hedrocel

Resumen (EN)

Between 2000 2002 we treated 18 patients with
symptomatic osteoarthritis or osteonechrosis of hip, with
uncemneted Thrust Plate Protesis (Sulzer) and tantalium acetabular
componente Hedrocel (Zimmer), with ceramic-polyethylene
pair. The average age of the patients was 46,7 years
(range:35-61), and the average follow-up of 42 months.
Clinical evaluation was done with Merle D'Augbigné Postel's
scale obtaining 38,8 % of excellent results, 22,2 % of good
results, 11,1 % fair and 27,4 % poor (5 cases). Four cases needed
re-operation for loosening of the femoral stem. There was
no failure of the acetabular component. The hip artrhroplasty
in the young patients need solutions with the minor resection
of bone, but this model of femoral stem does not give a satisfactory
result, therefore we have abandoned it.

Explorar

Artículos


Volúmenes


Sobre la revista


Más leídos

Surgiceloma como complicación de tenodesis extraarticular de Lemaire modificada asociada a ligamentoplastia del cruzado anterior

Revista Española de Cirugía Osteoarticular


Uso de placa puente dorsal: una alternativa en fracturas de muñeca catastróficas

Revista Española de Cirugía Osteoarticular


No todo es "cut-out": reclasificación de las complicaciones mecánicas del tornillo cefálico del clavo intramedular.

Revista Española de Cirugía Osteoarticular


Solución límite para recambio de prótesis total de cadera con cotilo osteointegrado: presentación de casos

Revista Española de Cirugía Osteoarticular


Radioterapia a bajas dosis en artrosis: ¿una opción terapéutica real o un efecto placebo sofisticado?

Revista Española de Cirugía Osteoarticular