27-162

La consolidación de las fracturas diafisarias del radio en el adulto. Resultados del tratamiento con osteosíntesis por autocompresión.

SHAFT FRACTURES HEALING OF RADIUS TREATED BY COMPRESIÓN BONE PLATING

R. GUARNIERO, T.E. PESSOA DE BARROS FILHO, O. PIRES DE CAMARGO y G.E. CARDENAS ARENAS. Departamento de Ortopedia y Traumatología. Facultad de Medicina de Sao Paulo. Brasil.
Recepción:
14/01/2009
Aceptación:
14/01/2009
Publicación:
14/01/2009


Métricas


40

Visualizaciones


Compartir

Compartir

Resumen (ES)

The authors carried out an analysis of healing in shaft fractures of radiustreated by compression bone plating (Bagby System). 30 patients treated in theDepartment of Orthopaedic Surgery of "Hospital das Clínicas" (F.M.U.S.P.) between1975 and 1985 were includedin this study. 24 (80%) of patients were men and 6 (20%)women; average of age was 30.1 years (rangel8-47). Bagby plates with 4 and 6 screws(18 and 6 cases respectively) were used by the authors. Good results were obtained in24 patients, fair in 4 cases of delayed union were observed. The average of healing was9 weeks (6-16). One patient showed dehiscence of the wound, and other allergic reactionto metal. Two patients had paresia of radial nerve resolved spontaneously. In threecases, showed local osteoporosis after the plate was removed. No cases of refracturewere observed in this series.

Palabras clave (ES):

Consolidación
Tratamiento
Autocompresión
Quirúrgico
Diáfisis
Fractura
Diafisaria
Radio
Placa
Compresión
Osteosíntesis

Resumen (EN)

The authors carried out an analysis of healing in shaft fractures of radiustreated by compression bone plating (Bagby System). 30 patients treated in theDepartment of Orthopaedic Surgery of "Hospital das Clínicas" (F.M.U.S.P.) between1975 and 1985 were includedin this study. 24 (80%) of patients were men and 6 (20%)women; average of age was 30.1 years (rangel8-47). Bagby plates with 4 and 6 screws(18 and 6 cases respectively) were used by the authors. Good results were obtained in24 patients, fair in 4 cases of delayed union were observed. The average of healing was9 weeks (6-16). One patient showed dehiscence of the wound, and other allergic reactionto metal. Two patients had paresia of radial nerve resolved spontaneously. In threecases, showed local osteoporosis after the plate was removed. No cases of refracturewere observed in this series.