29-169

Alteraciones fisarias tras radiación láser

PHYSEAL DAMAGE AFTER LASER RADIATION

A. MAESTRO* A. PÉREZ CASAS** M. E. BENGOECHEA** y A. MURCIA* * Servicio de Cirugía Ortopédica y Traumatología. Hospital de Cabueñes. Gijón. ** Departamento de Morfología y Biología Celular. Universidad de Oviedo.
Recepción:
12/01/2009
Aceptación:
12/01/2009
Publicación:
12/01/2009


Métricas


54

Visualizaciones


Compartir

Compartir

Resumen (ES)

In view of the present importance of Laser Radiation, and due to the lack ofreferences about its effects on the growth cartilage, we designed an experimental model in orderto asses it. A total of 50 rats were used, establishing five groups of study at 10 animals each,depending on the dosis of radiation applied percutaneously on the distal femoral phisys. Afterthe structural, histochemical and morphometric study, we observed a series of alterations indicatinga direct celular damage at the physion. From the results, it is concluded that laserradiation should be on absolute contraindication during the phase of bone growth or in the inmatureskeleton.

Palabras clave (ES):

Lesión
Fisis
Cartílago
de
crecimiento
Radiación
Láser

Resumen (EN)

In view of the present importance of Laser Radiation, and due to the lack ofreferences about its effects on the growth cartilage, we designed an experimental model in orderto asses it. A total of 50 rats were used, establishing five groups of study at 10 animals each,depending on the dosis of radiation applied percutaneously on the distal femoral phisys. Afterthe structural, histochemical and morphometric study, we observed a series of alterations indicatinga direct celular damage at the physion. From the results, it is concluded that laserradiation should be on absolute contraindication during the phase of bone growth or in the inmatureskeleton.

Explorar

Artículos


Volúmenes


Sobre la revista


Más leídos

Surgiceloma como complicación de tenodesis extraarticular de Lemaire modificada asociada a ligamentoplastia del cruzado anterior

Revista Española de Cirugía Osteoarticular


Uso de placa puente dorsal: una alternativa en fracturas de muñeca catastróficas

Revista Española de Cirugía Osteoarticular


No todo es "cut-out": reclasificación de las complicaciones mecánicas del tornillo cefálico del clavo intramedular.

Revista Española de Cirugía Osteoarticular


Solución límite para recambio de prótesis total de cadera con cotilo osteointegrado: presentación de casos

Revista Española de Cirugía Osteoarticular


Radioterapia a bajas dosis en artrosis: ¿una opción terapéutica real o un efecto placebo sofisticado?

Revista Española de Cirugía Osteoarticular