29-170

Artroplastia total de cadera Bihapro® Primeros resultados

TOTAL HIP ARTHROPLASTY USING THE BIHAPRO® MODEL

D. HERNÁNDEZ VAQUERO*, J. PAZ JIMÉNEZ**, A. MURCIA MAZÓN***, R. ALEGRE MATEO*, J. AMADOR MELLADO** y C. RENDUELES MENÉNDEZ Departamento de Cirugía y Especialidades Médico-Quirúrgicas. Facultad de Medicina. Universidad de Oviedo. * Hospital «San Agustín», Avilés. ** Hospital Central, Oviedo. *** Hospital de Cabueñes, Gijón.
Recepción:
12/01/2009
Aceptación:
12/01/2009
Publicación:
12/01/2009


Métricas


58

Visualizaciones


1

Descargas


Compartir

Compartir

Resumen (ES)

In this report we review 150 total hip arthroplasties performed in three hospitalswith a follow-up of 3 to 15 months. In all cases were used the Bihapro® model made of Titaniumalloy with a hidroxiapatite coated femoral component in its proximal region. The age ofthe patients varies from 29 to 76 years, with an average of 61 years. Although the follow-upperiod is short the authors show both a good clinical evolution with little thigh pain and an excelentacetabular bone integration with areas of osteocondensation and trabeculae in the femoralmetaphyseal area.

Palabras clave (ES):

cementada
Hidroxiapatita
Cadera
Prótesis
Artroplastia
Resultado
Bihapro
No

Resumen (EN)

In this report we review 150 total hip arthroplasties performed in three hospitalswith a follow-up of 3 to 15 months. In all cases were used the Bihapro® model made of Titaniumalloy with a hidroxiapatite coated femoral component in its proximal region. The age ofthe patients varies from 29 to 76 years, with an average of 61 years. Although the follow-upperiod is short the authors show both a good clinical evolution with little thigh pain and an excelentacetabular bone integration with areas of osteocondensation and trabeculae in the femoralmetaphyseal area.

Explorar

Artículos


Volúmenes


Sobre la revista


Más leídos

Surgiceloma como complicación de tenodesis extraarticular de Lemaire modificada asociada a ligamentoplastia del cruzado anterior

Revista Española de Cirugía Osteoarticular


Uso de placa puente dorsal: una alternativa en fracturas de muñeca catastróficas

Revista Española de Cirugía Osteoarticular


No todo es "cut-out": reclasificación de las complicaciones mecánicas del tornillo cefálico del clavo intramedular.

Revista Española de Cirugía Osteoarticular


Solución límite para recambio de prótesis total de cadera con cotilo osteointegrado: presentación de casos

Revista Española de Cirugía Osteoarticular


Radioterapia a bajas dosis en artrosis: ¿una opción terapéutica real o un efecto placebo sofisticado?

Revista Española de Cirugía Osteoarticular