29-171

Respuesta ósea al implante del compuesto beta-fosfato tricálcico-colágeno (ß-FTC-C). Estudio «in vivo» en conejos

BONE RESPONSE TO P-TRICALCIUM PHOSPHATE-COLLAGEN COMPOSITE. AN IN VIVO STUDY IN RABBITS

L. R. MESEGUER OLMO, M. ALCARAZ BAÑOS, V. VICENTE ORTEGA. M. CLAVEL-SAINZ NOLLA y A. GALIAN CÁNOVAS Laboratorio de. Cirugía Ortopédica Experimental. Facultad de Medicina. Universidad de Murcia.
Recepción:
09/01/2009
Aceptación:
09/01/2009
Publicación:
09/01/2009


Métricas


54

Visualizaciones


Compartir

Compartir

Resumen (ES)

The correlation between histologic and radiological findings was studied afterimplantation of a composite (ß-FTC-C) into osseus defects which were experimentally inducedin 21 rabbits. Under general anaesthetic osseus defects were made in both femurs and filledin with a 4,5 x 6 mm composite cylinder. The animals were killed at the first week and,one, two, four and twelve months after surgery. X-ray study and microscopic examinationwere made in all the specimens. Troughout the implantation period, it was microscopicallyproven that the composite showed a progressive reabsortion process, mediated by cells ofmacrophagus lineage. A decrease in radiologic density and changes in its morphology werealso observed. At the end of the study (twelve months), limited traces of the material couldbe seen, in correlation with the images of the X-ray films which revealed the total absence ofthe composite implant.

Palabras clave (ES):

Sustituto
Fosfato
tricálcico
Colágeno
óseo
Experimental
Defecto
óseo
Reparación
ósea

Resumen (EN)

The correlation between histologic and radiological findings was studied afterimplantation of a composite (ß-FTC-C) into osseus defects which were experimentally inducedin 21 rabbits. Under general anaesthetic osseus defects were made in both femurs and filledin with a 4,5 x 6 mm composite cylinder. The animals were killed at the first week and,one, two, four and twelve months after surgery. X-ray study and microscopic examinationwere made in all the specimens. Troughout the implantation period, it was microscopicallyproven that the composite showed a progressive reabsortion process, mediated by cells ofmacrophagus lineage. A decrease in radiologic density and changes in its morphology werealso observed. At the end of the study (twelve months), limited traces of the material couldbe seen, in correlation with the images of the X-ray films which revealed the total absence ofthe composite implant.

Explorar

Artículos


Volúmenes


Sobre la revista


Más leídos

Surgiceloma como complicación de tenodesis extraarticular de Lemaire modificada asociada a ligamentoplastia del cruzado anterior

Revista Española de Cirugía Osteoarticular


Uso de placa puente dorsal: una alternativa en fracturas de muñeca catastróficas

Revista Española de Cirugía Osteoarticular


No todo es "cut-out": reclasificación de las complicaciones mecánicas del tornillo cefálico del clavo intramedular.

Revista Española de Cirugía Osteoarticular


Solución límite para recambio de prótesis total de cadera con cotilo osteointegrado: presentación de casos

Revista Española de Cirugía Osteoarticular


Radioterapia a bajas dosis en artrosis: ¿una opción terapéutica real o un efecto placebo sofisticado?

Revista Española de Cirugía Osteoarticular